環境工学研究論文集
Online ISSN : 1884-829X
Print ISSN : 1341-5115
ISSN-L : 1341-5115
高負荷条件の浸漬膜式活性汚泥プロセスにおける膜汚染に対する膜分離孔径の影響
堀 晃士小野 徳昭依田 元之
著者情報
ジャーナル フリー

2002 年 39 巻 p. 503-510

詳細
抄録
To achieve higher organic loading with submerged membrane separation activated sludge (SMAS) process, effects of membrane pore size ranging from 0.03μEm to 0.4μEm on membrane fouling was investigated using pilot-scale plant with synthetic wastewater. The putative membrane foulants, colloidal microbial products (CMP) were similarly rejected regardless of the membrane pore sizes, while the increase in transmembrane pressure (TMP) with the 0.4μEm was much higher as compared to the 0.1μEm. Since the fouling was irreversible through physical cleaning operation in all the case, it was thought that CMP was trapped inside the membrane structure, and that larger pore size as 0.4μEm traps larger amount of CMP, causing greater TMP. With the membrane pore size of either 0.03μEm or 0.1μEm, continuous operation of SMAS for almost two months was possible, but requires further investigation for more stable operation.
著者関連情報
© 社団法人 土木学会
前の記事 次の記事
feedback