下水処理における地球温暖化ガスの実態調査
岡山 安幸神代 和幸鈴木 學谷口 正人
著者情報
ジャーナル フリー

2001 年 9 巻 p. 285-289

詳細
抄録
The concentration of CH4, CO2 and N2O discharged from treatment processes of a municipal sewerage plant where activated sludge processes have been operated were measured between October 2000 and March 2001, and following results were obtained.
1) Emission of CH4 was significant at both receiving and pre-aeration tanks in the clarifier.
2) Great amount of CO2and N2O gas was emitted from the aeration tanks. In particular, emission of N2O was largely correlated with NO2-N concentration.
3) Generation of global-warning-gas from the sewerage plant was calculated as 650, 94200, and 82kg/day for CH4, CO2and N2O, respectively.