品質工学
Online ISSN : 2189-9320
Print ISSN : 2189-633X
ISSN-L : 2189-633X
開発と研究
増幅器安定化設計
河田 直樹金本 良重山本 雅男矢野 宏
著者情報
ジャーナル フリー

1996 年 4 巻 3 号 p. 69-81

詳細
抄録
Quality Engineering approaches have been applied in the area where electronic characteristics are used. ln some cases however, it happened that there was no reproducibility in the gain on SN ratio. In this paper, a simple transistor amplifying circuit was used to study the problem, Historically,design targets have been met through adjustment or tuning. But from quality engineering viewpoint, it is necessary to discuss the experimental techniques, circuit constants or the selection of control factors, etc. From the study, the following were concluded: (1) The characteristics of measuring equipment have considerable impact to SN ratio and sensitivity. (2) lt is necessary to consider circuit capability for the determination of the signal factor. (3)Depending on the way of setting the control factors of circuit elements, the circuit characteristics may be changed.
著者関連情報
© 1996 一般社団法人 品質工学会
前の記事
feedback
Top