RADIOISOTOPES
Online ISSN : 1884-4111
Print ISSN : 0033-8303
ISSN-L : 0033-8303
Note
Measurement of Exposure Dose and Its Reduction Design for Nurses in Charge in FDG-PET/CT with Contrast Reviewing the Manual and Staff Flow Line
Rie KASHIWAZAKIShigeko TOCHIGIMichiko ONUKIKazufumi SUZUKISetsu SAKAMOTO
Author information
JOURNAL OPEN ACCESS

2013 Volume 62 Issue 11 Pages 827-832

Details
Abstract

Nurses in charge received additional radiation exposure from the patients with intravenous FDG injection when FDG-PET/CT with contrast media was performed. The exposure dose was measured about 1.5μSv per examination on average. There was not a large difference among those when the mean exposure dose of each nurse was compared. There was a tendency that the exposure dose was less, as work years of the nurses in charge of PET/CT with contrast were longer. Consideration of radioactivity distribution in the PET/CT examination room has a potential to reduce radiation exposure dose of the nurses in charge.

Content from these authors
© 2013 by Japan Radioisotope Association
Previous article Next article
feedback
Top