Determination of the Dew Point and the Frost Point below 0°C Making Use of the β-Ray Backscattering and the Electric Conductivity on the Narrow Surface of Insulated Layer
Shigeaki MATSUMOTOHisanobu KOBAYASHI
Author information
JOURNAL FREE ACCESS

1979 Volume 28 Issue 10 Pages 609-612

Details
Abstract
It is necessary to distinguish between the dew point and the frost point below 0°C. The freezing of the dew and the melting of the frost are respectively detected by the rapid decrease and the increase of the conduction current on the narrow surface of insulated layer made of epoxy, 0.5 mm in width and 10 mm in length, on which the dew deposits. The dew point -9°C and the frost point -8°C in the humidity 21% at the temperature 13°C are clearly distinguished in this method.