1988 Volume 37 Issue 2 Pages 63-68
Feasibility of TS-16N solid state nuclear track detectors for an imaging medium of rapid autoradiography of a-emitters is described. Though a little longer etching time was required, the contrast of autoradiographic image on this detector proved to be superior to CR-39 detectors whose property for macroautoradiography was previously reported by the authors. The resolutions of these two different type detectors were almost equivalent to each other. The autoradiography taken by way of trial proved that this detector could be used to study metabolism and dosimetry of internally deposited a-emitters. With further study, the inherent properties of this detector such as low background or high sensitivity should extend the field of track etch imaging technique such as fast neutron radiography.