2007 Volume 56 Issue 9 Pages 497-508
The authors calculated anisotropy factors for 241Am-Be neutron sources used for calibration of neutronmeasuring devices for radiation protection purpose. In this calculation, we created a calculation model composed of following three steps: (1) calculation of α-particle spectrum at the surface of spherical cluster of AmO2, (2) calculation of neutron yield in a thick beryllium target and of neutron spectrum produced by 9Be (α, n) reactions ; and (3) calculation of angular fluence distribution of neutrons emerging from two different encapsulation types of 241Am-Be neutron sources. This computation was made by combining an in-house code using the 9Be (α, n) cross section data library (JENDL/AN-2005) and the Monte Carlo code MCNP-4C. As a result, anisotropy factors in the direction perpendicular to the source capsule axis were evaluated to be 1.030 and 1.039 for 241Am-Be in a standard Amersham X3 capsule and X4 capsule, respectively. These values are in reasonable close agreement with the published experimental data. If the support structures are included in the simulation, the anisotropy factors for these neutron sources increase by about 10%.