Abstract
To develop appropriate evaluation methods and improve reliability, it is very important to identify failure mechanism accurately. In this thesis, a case study is reported where FTA is employed for failure analysis of a resin sealed thermistor sensor. By introducing the design of experiments, failure physics, and making efficient use of existing data collected in the field and process in the course of analysis, the failure mechanism was identified efficiently and accurately, successfully developing a new evaluation method and improving reliability.