Rigakuryoho Kagaku
Online ISSN : 2434-2807
Print ISSN : 1341-1667
ORIGINAL ARTICLE
Reliability and Validity of Direct Arch Measurement under Quantitative Partial Weight Bearing
Takehiro OHMIJunya AIZAWAKenji HIROHATAShunsuke OHJIKazuyoshi YAGISHITA
Author information
JOURNAL OPEN ACCESS

2020 Volume 35 Issue 2 Pages 179-185

Details
Abstract

[Purpose] Direct arch measurement under quantitative partial weight bearing (DAM-under-qPWB) has been developed as a new method for measuring the medial longitudinal arch. This study examined the reliability and validity of DAM-under-qPWB with respect to the navicular drop test (NDT). [Participants and Methods] The participants were 12 young adults and a total of 24 feet were measured. DAM-under-qPWB was measured under 2 conditions, namely, 50% and 100% weight-bearing. Two testers were responsible for recording the measurements. The inter- and intra-class correlation coefficients for the 2 testers were determined. To quantify the validity, the correlation between DAM-under-qPWB and NDT was determined. [Results] DAM-under-qPWB was confirmed to have high reliability in this study. Correlation analysis revealed a significant correlation between DAM-under-qPWB and the NDT. [Conclusion] The findings of this study suggest that DAM-under-qPWB can be used for the evaluation of the medial longitudinal arch.

Content from these authors
© 2020 by the Society of Physical Therapy Science

この記事はクリエイティブ・コモンズ [表示 - 非営利 - 改変禁止 4.0 国際]ライセンスの下に提供されています。
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.ja
Previous article Next article
feedback
Top