Quarterly Report of RTRI
Online ISSN : 1880-1765
Print ISSN : 0033-9008
ISSN-L : 0033-9008
PAPERS
Evaluation of Level Crossing Lightning Protection Measures
Hideki ARAIHiroyuki SUGAHARAKazutoshi SATO
著者情報
研究報告書・技術報告書 フリー

2005 年 46 巻 2 号 p. 118-123

詳細
抄録
Building up effective and economical countermeasures is needed to prevent lightning damage to railway signalling systems. Therefore, we measured the wayside ground potential distribution when a rail potential rise was caused by injecting a lightning surge current into a rail. Moreover, we injected a lightning surge current into the rail or wayside ground, raising their potential in order to measure the lightning overvoltages on a level crossing so that basic insulation design data could be obtained. This paper demonstrates that an effective countermeasure is to earth lightning protective devices, which are attached to the electronic train detectors on a level crossing to suppress any lightning overvoltages.
著者関連情報
© 2005 by Railway Technical Research Institute
前の記事 次の記事