Quarterly Report of RTRI
Online ISSN : 1880-1765
Print ISSN : 0033-9008
ISSN-L : 0033-9008
PAPERS
Evaluation of Shear Capacity of RC Pile Head Based on Equivalent Shear Span Method
Yuki NAKATAHaruyuki KITAGAWAKen WATANABEToshiya TADOKORO
著者情報
研究報告書・技術報告書 フリー HTML

2025 年 66 巻 3 号 p. 141-147

詳細
抄録

In the verification of reinforced concrete (RC) piles, the design shear capacity Vyd of linear members is used based on the experimental results of simply supported RC beams. On the other hand, since RC piles are subjected to ground reaction forces, the shear capacity may be greater than Vyd, unlike simply supported conditions. In this paper, we have used nonlinear finite element analysis to evaluate the shear capacity of RC pile heads taking into account ground reaction forces. We have shown that the equivalent shear span method, which is applied to the analysis of slabs of underground box structures, can also be applied to the analysis of RC pile heads.

著者関連情報
© 2025 by Railway Technical Research Institute
前の記事 次の記事
feedback
Top