ワークショップ:タンパク分画用の新規セルロースアセテート膜,セレカVSPの性能評価
全自動電気泳動装置(常光CTEシリーズ)による新しいセルロースアセテート膜‘セレカ-VSP’の基本性能評価
小野寺 和彦石原 清隆有園 秀敏
著者情報
ジャーナル フリー

2007 年 51 巻 2 号 p. 105-107

詳細
抄録

As a cellulose acetate membrane for serum protein fraction test, SELECA-VSP has been developed to substitute for SEPARAX-SP. Then we investigated whether SELECA-VSP can be used for protein fraction test by use of full-automated electrophoresis system (JOKOH CTE series).
A difference was observed in the A / D sensor level detecting that SELECA-VSP fed into buffer bath because SELECA-VSP was thinner than SEPARAX-SP. Therefore, the adjustment of the A / D sensor level is possibly required when SELECA-VSP is substituted for SEPARAX-SP.
On the other hand, there were no difference in membrane feeding test, electrophoretic properties and measured percentage of each protein fraction of control serum. Slight change in the full-automated electrophoresis system parameter easily leads to apply SELECA-VSP to routine laboratory test using JOKOH CTE series electrophoresis system.

著者関連情報
© 2007 日本電気泳動学会