G-9 A Study on Characteristics of Environment in Oasis 21 : (Part 2) Characteristics of the Wind Environment
Akihiro NAGATAHisaya ISHINOKimiko KOHRITatsuo NAGAIHiroshi OHGA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
The underground open space in OASIS 21 is a semi-outdoor space. It has a glass roof with a pond but has no wall above ground. Therefore its environment is strongly influenced by the natural wind. In this study, ultrasonic anemometers are placed above the glass roof and in the underground space to measure wind speed and direction. The vertical velocity distribution in the underground space and the wind speed and direction of underground pathways are also measured.