Abstract
It is difficult for practitioners to perform the sophisticated moisture transfer calculations. Knowledge of internal condensation is not enough for practitioner. Based on these background, We developed simplified calculation method based on steady state calculation method involving absorption and desorption. According to concluding remarks of comparison with precise calculation method and experiment, simplified method quite agree well with precise method and experiment with glass fiber insulation.