The purpose of this basic research is to produce well-grounded data about performance evaluation and the design technique of a disposer drainage system, The important point of a disposed food waste grinder drainage system of performance evaluation is securing a carrying performance between the horizontal drainage pipes. In this report is described that tractive force required in order to make food waste deposited within the horizontal drainage piping is examined by small piping model.
View full abstract
-
Manabu YAMAMOTO, Sadanori KODERA, Masayuki OTSUKA, Satoru KOSHIMIZU, C ...
Article type: Article
Session ID: A-20
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
We have done an investigation and a survey on usage frequency, amount of kitchen garbage, and user1s satisfaction valuation of the disposer drainage system at a super high-rise apartment. As result, residents who mainly eat at home use the disposer 2.6 times a day, where those who mainly eat out use the disposer once per two days. Most of the people uses the disposer for approximately 20 seconds each time, and was concentrated at night time. The satisfactory rate of the system was as high as 65%. However, the noise and vibration were the main factors of the dissatisfaction.
View full abstract
-
Toshihiro SANKAI
Article type: Article
Session ID: A-21
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
On this paper, some results of this studies are reported as follows: - Outline of studies - Actual situation of garbage disposal in farming area - Results of questionnaires concerning understanding of resident about garbage disposal
View full abstract
-
Toshihiro YAMATE
Article type: Article
Session ID: A-22
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The galvanic corrosion is generated by the joint of the galvanized steel pipe and the gunmetal. To prevent the galvanic corrosion of the galvanized steel pipe and the gunmetal, the effect of measures by the vacuum membrane deaeration system was examined by the experiment with the water loop piping system and the basic electrochemical measurements. It was clarified that the galvanic corrosion of the galvanized steel pipe and the gunmetal could be prevented by the vacuum membrane deaeration system.
View full abstract
-
Chisao YONEDA, Masayuki OTSUKA, Masanobu YUZAWA, Takahiro KOIKE, Hidey ...
Article type: Article
Session ID: A-23
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This report is concerned with an investigation for the equipment piping etc. of the institution named "Osawa Memorial Institute of Architectural Environmental Engineering, Kanto Gakuin University" which has been 36 years after built at the Kanto Gakuin University. Some ways of inspection have been performed for many sorts of pipes in this investigation. In this report, we studied the grade of result on this inspection, and tried to compare non-breaking inspection with cutting sample measurement.
View full abstract
-
Kiichi TAKEDA, Tsutomu NAKAMURA, Tomoo INADA, Hironobu KIDO, Yoshito O ...
Article type: Article
Session ID: A-24
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
It made sample according to plasticizer the chlorine resistance efficiency of the synthetic rubber and it implemented dipping examination by chlorine water. The result is shown below. 1) The plasticizer most superior in the chlorine resistance efficiency was aroma oil. 2) With naphthene oil, outbreak of hole was accepted. 3) A crack occurred by paraffin combination.
View full abstract
-
Hiroshi Tomonari, Yaoui Wang, Motoyasu Kamata, Kyosuke Sakaue
Article type: Article
Session ID: A-25
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
As a first verification theme of the three-dimensional numerical computation on traps with seal loss occurrence,self-siphonage type WC was selected. Using a model closet simulating the water passage of the WC,mass balance before and afer the self siphonage and transient response to the pressure in the trap were compared. It has been comfumed that the computation has sufficient accuracy in analyzing drainage
View full abstract
-
Yue ZHANG, Motoyasu KAMATA, Kyousuke SAKAUE, Takayuki TOYAMA
Article type: Article
Session ID: A-26
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this paper, the reproducibility of the testing device for trap performance using by the new wavy generator control software is confirmed. Six kinds of traps were used the experiment by the drainage experiment system to examine the relation between the pressure and the seal water loss. And in addition, the pressure wave obtained by the drainage experiment system was used for the experiment by the testing device for trap performance.
View full abstract
-
Akio UEMIYA, Tomoya KANEKO, Tetsu KONDO
Article type: Article
Session ID: A-27
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This report focuses on utilizing RFID for the flow examination of drainage system with the goal to improving the efficiency of operation and the quality of the flow examination. This report provides the brief of the RFID-Based Flow Examination System and the results from the demonstration of this system in a new office building project.
View full abstract
-
Yuuji Tanno, Seiji Kaneko, Junpei Nobayashi
Article type: Article
Session ID: A-28
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Floor drains for the rain water drainage are installed in balcony and corridor at the buildings. The dispersion phenomenon of rain water happens in the existing drain for relay when rain water is drained directly from the rooftop to the relay drain. In recent years, the local heavy rain by the abnormal weather is increasing. In that case, the balloon phenomenon of rain water happens when the rainfall increases.In order to reduce this phenomenon roughly, we researched floor drains of funnel structure.
View full abstract
-
Kazuhiro SHIGETA, Masayuki OTSUKA, Takeshi AOI, Koichi KAWASAKI, Norih ...
Article type: Article
Session ID: A-29
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The purpose of this study is to propose the evaluation method for drainage performance with air admittance valve (AAV),which is applied to drainage stack system in high rise apartment houses. This paper discusses the investigation of propose the positive pressure control method by using two kinds of device. One is improvement of house drain size and the other is application of positive pressure attenuation device. As a result of this study, authors grasped the characteristic of positive pressure generation and efficiency of positive pressure relief.
View full abstract
-
Hirofumi YAGI, Kyosuke SAKAUE, Yoshifumi IIDA, Hideo YAMAGA, Takayuki ...
Article type: Article
Session ID: A-30
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
We carried out the drainage load test about the special drainage fitting system that has the drainage stack connecting the bottom floor branch pipe, and investigated the air pressure in the drainage stack due to the change of the piping layout and the drainage load. And we examined the shape of the fitting using the bottom floor connection and the method to reduce a positive pressure In the drainage stack at the bottom floor level.
View full abstract
-
Yoshifumi IIDA, Kyosuke SAKAUE, Hirofumi MAGI, Takayuki TOYAMA, Yu AID ...
Article type: Article
Session ID: A-31
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this report, studies were conducted on the connection of branch pipes to stack pipe on the lowest floor of building. In order to seek the possibility of connecting branch pipes above floor, experiments on drainage system were carried out based on the proviso of SHASE-S206-2000,
View full abstract
-
Kouji OKUMURA, Toshihisa MATSUSHIMA, Takeshi ISHII, Satoshi ICHINOSAWA ...
Article type: Article
Session ID: A-32
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Generally, typical apartment houses are equipped with a drainage system with special fittings. However, a horizontal branch on the lowest level of pipe-lines does not combine with a drainage stack system. They are usually installed as individual pipe-lines separately. Since there are high demands for reducing the amount of labor for installing the horizontal branches on the lowest level of pipe-lines and improving clog-up problems, this study is to discuss a design method for combining the drainage stack system to horizontal branches on the lowest level of pipe-lines and its feasibility.
View full abstract
-
Shuichi ISHIMURA, Takaaki KOGA, Kyosuke SAKAUE, Nobuyuki TSUKAGOSHI, K ...
Article type: Article
Session ID: A-33
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
NCDS is a siphon drainage system using a slim pipe. But, the drain-characteristic of the system has not been so clarified, although a lot of advantages, because it is very different from a traditional system in the substitution of air and water. We made a device that is able to set the pipe freely, and understood the basic drain-characteristic, by observations of air-movements in the pipe and of flow reductions for the residual air. Moreover, to deepen the research in the future, we are proposing the new terms about the characteristic phenomena and the flows.
View full abstract
-
Sadanori KODERA, Manabu YAMAMOTO, Nobuyuki TSUKAGOSHI, Kyosuke SAKAUE, ...
Article type: Article
Session ID: A-34
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The dwelling unit which wash equipment of exclusive use by the apartment of the Showa 30s cannot install yet connects the drainage -- standing -- the drainage capability of a pipe -- it is necessary to stand and to solve the problem of the distance to a pipe Then, in order to check the conformity of a system connectable with drainage pipe only for washbasins paying attention to a siphon drainage system, the instrument drainage characteristic was measured.
View full abstract
-
Nobuyuki TSUKAKOSHI, Sadanori KODERA, Manabu YAMAMOTO, Kyosuke SAKAUE, ...
Article type: Article
Session ID: A-35
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This research is the report are the proposal of extension of the washing machine drainage to thin established drainage vertical pipe made conventionally impossible being attained, and carry out that the evaluation was proved by the drainage experiment by using together the new drainage unification method to drainage vertical pipe developed uniquely with application of the low drainage load characteristic which a byway drainage system has.
View full abstract
-
Takahiko SUZUKI, Masayuki OTSUKA, Kazuhiro SHIGETA, Yusuke MINAMI
Article type: Article
Session ID: A-36
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The study is aimed at the performance evaluation and design method of the horizontal fixture drain branch pipe system, that is designed particularly for SI housing. In this paper, the authors pay attention to a sanitary drain system analysis unfinished and a change of a drainage characteristic value and examine the influence that a difference of a piping condition gives to carrying performance. The authors describe the knowledge obtained from particularly average flow a fixture, carrying performance, tractive force and water level in pipe as an evaluation index.
View full abstract
-
Hideki YOSHITOMI
Article type: Article
Session ID: A-37
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The accident of engulfing human body in the drain port of swimming pool has happened. So, we have studied new safety drainpipe with vortex chamber in order to free from the danger. The proposed drainpipe can control the suction force with the working of water flow itself without any mechanical equipment. In previous report, the suction force and basic flow properties of the drainpipe were analyzed experimentally. This paper is the 3rd report, and we showed the performance prediction method by the modeling of internal flow.
View full abstract
-
Seizo KOJIMA, Masayuki OTSUKA, Takeshi AOI, Kazuhiro SHIGETA
Article type: Article
Session ID: A-38
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study is aimed at the development of renewal method on drainage system for stock housing. The corrosion of drainage pipes and executio performance of drainage system with special fitting was also discussed in the previous paper. This paper discussed the result of drainage performance test, which was conducted by using of the experimental tower. As a result, the authors grasped the flow capacity (in case of normal flow and the bubble water flow) and evaluated the efficiency of this renewal system.
View full abstract
-
Takeshi AOI, Masayuki OTSUKA, Kazuhiro SHIGETA, Seizo KOJIMA
Article type: Article
Session ID: A-39
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study is a follow up of an experiment study aimed for development of Renewal method of drainage system of stock housing. This paper assumed a drainage system of a previous report and confirmed performance and update use influence drainage that used a fitting for stock housing, and performance of a drainage pipe of existing multifamily housing. As the result, examined the effectiveness of update use drainage performance that used a fitting for stock housing.
View full abstract
-
Susumu TAKACHI
Article type: Article
Session ID: A-40
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this report, the writer investigated the number of grease interceptor sold in 2004 by ten companies of the interceptor association of Japan, and then summarized the sales trend compared with the result in 1991 and 1995. As result of that, it became clear that grease interceptor laid to the cinder concrete above the floor in the kitchen increasing rapidly.
View full abstract
-
Kaori KOBAYAKAWA, Kazuya KOMINAMI, Susumu TAKACHI
Article type: Article
Session ID: A-41
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
There is no a clear standard without establishing the place technical standard by the present in oil-interceptor collection vessel installed under drainage in including oil-interceptor and parking lot it hinders the gravel, and it does the collection. In this paper, for the purpose of collecting the data as a base of the technical standard of the oil hindrance collection vessel, the situation of domestic and overseas is investigated, and it reports this, because some experiments were carried out.
View full abstract
-
Kunihiro HOSHINO, Shinsuke KATO, Yuji ATAKA
Article type: Article
Session ID: B-12
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
It is examined as a standardized method for the Micro chamber method to measure SVOC emitted from building materials. DEHP is classified as SVOC and widely used as plasticizers in polyvinyl chloride (PVC). The indoor guideline of the Japan Ministry of Health, Labour and Welfare for DEHP was set at 120 μg/m^3. In this study, the authors measured DEHP emitted from PVC wallpaper and flooring using the Micro chamber method. And we evaluated various experiments concerning this method. In these experiments it was found that the silane finishing of the internal chamber surface was effectively in the measurement of SVOC emitted.
View full abstract
-
Shin-ichi TANABE, Taisuke AOKI, Hideaki TANI
Article type: Article
Session ID: B-13
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Semi volatile organic compounds (SVOC) have high boiling points such as over 240 degrees Celsius. These high boiling points make it difficult to quantify SVOC concentrations with accuracy. In this study, the new measurement method was developed and descriptions of the method are shown in this paper. The method is evaluating SVOC amount by adsorbent amount to a glass plate, and to stabilize the amount the wind channel unit and fogging unit were developed. Also this paper reports the experiments to determine measurement conditions. It was found the wind channel unit stabilizes and increases the amount of SVOC adsorption to the plate.
View full abstract
-
Shin-ichi TANABE, TAISUKE AOKI, Hideaki TANI
Article type: Article
Session ID: B-14
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Because Semi volatile organic compounds (SVOC), such as phthalate esters and phosphate esters that are included in various building materials or household articles as plasticizers and flame retardants, have high boiling point, and the concentration is very low, there is a risk of underestimating the SVOC amount by a measurement method the same as VVOC and VOC. Therefore, for the purpose of evaluating utility of the SVOC measurement method with the glass plate which we developed, experiment of confirming contamination from a container and storage performance, experiment of measuring adsorbed amount of SVOC emitted from polyvinyl-chloride building materials in two kinds of chambers and survey of the extent of contamination in a house were done.
View full abstract
-
Hiroko KATSUMATA, Shuzo MURAKAMI, Shinsuke KATO, Kunihiro HOSHINO, Yuj ...
Article type: Article
Session ID: B-15
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This paper presents the study on environmental factors in SVOCs emitted from indoor materials under actual room conditions. Di(2-ethylhexyl)phthalate (DEHP), classified as a SVOC, is representative of most plasticizers. A recent report has found an association between asthma / allergic symptoms in children and DEHP in house dust. And so the authors notice the nature of DEHP, a tendency to be absorbed by solid surfaces, we investigate the influence of floating particles on the emission rate of SVOCs from materials. In these experiments we found the possibility that the floating particle1s concentration becomes higher, the emission rate becomes larger.
View full abstract
-
Yasuo KUWASAWA, Haruki OSAWA, Tetsuo FUJIMOTO
Article type: Article
Session ID: B-16
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The pollutant concentration in the indoor air has been influenced from adsorption and desorption with various materials in the room with the source and the ventilation situation. Then, the adsorption and desorption performance to those formaldehyde and VOC was experimentally examined about the material etc. indoors used well. As a result, the adsorption coefficient and the desorption coefficient were calculated and shown. Moreover, it was shown that a change with the lapse of time of each pollutant concentration was predictable.
View full abstract
-
Nobuhiro MIURA, Makoto YAMAGUCHI, Sinsuke KATO, Janghoo SEO
Article type: Article
Session ID: B-17
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This paper reports influence of adsorption at wall surface on material transfer rate characteristics and appropriate position for concentration measurment. Large-Scale Chamber, especially virtical laminar flow large chamber, is found to be useful for measurement of SVOCs emission rate from an electric appliance or furniture that is assembled various materials.
View full abstract
-
Takashi SHIMONOSONO, Tadayoshi OHKAWARA, Masahiro HORI
Article type: Article
Session ID: B-18
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Emulsion of chemical-adsorption polymer by graft polymerization developed for decreasing formaldehyde was also applied to odor gases. The material was evaluated by adsorption isotherm and concentration time courses with a small glass chamber of a circulation system and in field of new buildings. The polymer mixed to acryl resign paint effected on decreasing formaldehyde emitted from melamine resign. The polymer mixed to agar gel was effective on ammonia and formaldehyde. The polymer mounted on dry tofu refuse decreased rapidly concentration of ammonia.
View full abstract
-
Jang-hoo SEO, Shinsuke KATO, Yuji ATAKA, Satoko NAGAO
Article type: Article
Session ID: B-19
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Recently, passive adsorption building materials is widely used as a countermeasure of indoor air pollution. A test method for evaluating the ability of adsorptive building materials to reduce the concentration of formaldehyde is now under consideration. However, it is rare that case of a measurement of decreasing effect of VOCs concentration of adsorptive building material. In this paper, we evaluated measurement of decreasing effect of toluene concentration with activated carbon and absorptive building material by small test chamber method. And we consider that the influence factor of air exchange rate, product loading factor and mass per unit area affect experiment on decreasing effect of toluene concentration
View full abstract
-
Hoon KIM, Seung-Min LEE, Sueng-Jae LEE, Min-Ki SUNG, Hiroki HIGASHIDA, ...
Article type: Article
Session ID: B-20
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
From May 2004, indoor air quality control law regarding public buildings has been enforced in Korea. In Korea sick house syndrome has been a major social concern. Korean government supports research on the actual conditions of this subject and makes efforts to regulate indoor air pollution. This study has been conducted to understand the present state of indoor air pollution by chemical pollutants in newly built Korean housing. Investigation was conducted on indoor concentration of chemical pollutants, emission rate from building materials, ventilation rate, temperature and relative humidity. We used a passive measurement method developed by us, which is composed of passive diffusive samplers, ADSEC (Advanced Diffusive sampling Emission Cell) for emission rate, vials containing PFT for ventilation rate. A numerical calculation on air concentration and ventilation rate was conducted with COMIS.
View full abstract
-
Motoya HAYASHI, Haruki OSAWA, Miyuki MATSUI
Article type: Article
Session ID: B-21
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In order to estimate the influences of air pollutants from the concealed spaces to the indoor air quality, a slice model of Japanese common wooden structure was constructed in a laboratory. The model has two rooms on the first floor and two rooms on the second floor and also has a crawl space and two beam spaces. The equivalent leakage areas were measured using a multi fan system. The equivalent leakage areas between the concealed spaces were larger than those between the indoor spaces and the concealed spaces. The concealed spaces in the structure are connected very well.
View full abstract
-
Koji NETSU, Hiroshi YOSHINO, Koichi IKEDA, Atsuo NOZAKI, Kazuhiko KAKU ...
Article type: Article
Session ID: B-22
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In order to determine the factors of causes of SHS, a field survey on indoor air quality and occupants' health condition was conducted in 57 problematic houses, which is called as "sick house". In conclusion, formaldehyde, acetaldehyde and TVOC concentrations of many rooms exceeded the Japanese guidelines. While there were many substances emitted from construction materials, carbonyl compounds tend to be emitted from surface of interior finishing and furniture. While there were some occupants whose symptoms were relieved along with improvement of indoor air quality, some occupants' health conditions have not been changed.
View full abstract
-
Hiroshi NAKAGAWA, Masahiro TAKIGAWA, Hideo HASHIZUME, Akihiro OHSHIMA, ...
Article type: Article
Session ID: B-23
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Atopic dermatitis (AD) is a chronic pruritic skin disease affecting up to 20% of the general population. The disease occurs as a result of local and systemic skin hypersensitivity against environmental substances such as toxic inorganic substances. Here we show statistically significant improvement of the disease severity in patients hospitalized under standard treatments for 2 weeks in rooms with walls of diatomaceous earth compared with those in rooms without it. We therefore suggest that diatomaceous earth as the interior part of house containing is beneficial to patients with AD because of its excellent ability for humidity conditioning and gas absorbance.
View full abstract
-
Zhang Quan, S. Kato, Tsay Yaw-shyan
Article type: Article
Session ID: B-24
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
TVOCs (total organic compounds) emission process of the drying building materials belongs to interior control diffusion mode, so it influences indoor air quality in a long-term. The mixing ventilation is one of widely used modes in actual ventilation engineering application, which inflow concentration relates to outflow concentration and mixing ratio of fresh air and return air. Meaning while, the inflow velocity is usually varied based on the occupant exposure environment temperature. The impact of environment temperature on TVOCs emission rate also needs to consider during the program and simulation as well. The objective of this paper was to develop a user program to simulate the indoor TVOCs concentration distribution with the consideration of the above affecting factors under an integrated environment of FLUENT/UNIX 6.1.22. TVOCs concentration distribution features of indoor and inside the material were analyzed. The average concentrations of two occupant exposure zones with respect to time and TVOCs emission rate were also investigated. At last, the residual TVOCs percentage in the material was presented. The program and simulation are helpful for further research of healthy occupant environment and designing proper ventilation.
View full abstract
-
Disuke KATHIRA, Takashi AKIMOTO, Atsushi UETAKE, Qian YU
Article type: Article
Session ID: C-21
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Floor heating is one of the systems that does not cause any draft risk to warm up rooms. It was thought that floor cooling was also able to realize comfortable cooling environment without any local thermal discomfort. We conducted subjective experiments to evaluate thermal comfort of floor cooling in summer. Twelve experimental conditions were combinations of four-air temperatures and six-floor temperatures. Subjects felt comfort when both of air temperature range and floor temperature were from 26℃ to 29℃, and that temperature differences were within 3℃. The comfortable range of room and floor temperature combinations was investigated for floor cooling.
View full abstract
-
Hirokazu NAKAMURA, Tadahiko IBAMOTO, Kazumi NAKAYAMA, Kiyoshi TOKITSU
Article type: Article
Session ID: C-22
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Airflow, which is used as a control index for current general air conditioning systems, represents a stationary value or an average value, not including variable components such as air direction and air speed. In an actual environment, however, no airflow stays stationary, but instead, it always fluctuates. This system actively blows airflow to human bodies, and thereby changes the atmospheric environment periodically in a very short time. In this research, we conducted a study on understanding the room environment suitable for human, and a study on the effect of the breeze environment on productivity.
View full abstract
-
Kiyoshi TOKITSU, Tadahiko IBAMOTO, Kazumi NAKAYAMA, Sumiichi HAZAMA, K ...
Article type: Article
Session ID: C-23
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The cold air distribution system with fluctuating breeze need any other device than conventional air conditioning system. We have been studying feasibility for the whole of stage through construction Project. We would like to introduce principal issue of planning and designing stage, indoor environment. duct works, iVAV, and diffuser for instance.
View full abstract
-
Naoki KENMOTSU, Tadahiko IBAMOTO, Kazumi NAKAYAMA, Kiyoshi TOKITSU, Su ...
Article type: Article
Session ID: C-24
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
We found out some ropes of the smart planning to the cold air distribution system with fluctuating breeze through feasibility studies to construction project. We were to suggest designing process, heat load, a heat source system and so on. We will construct and operate this new HVAC system in next stage. We will be able to report concretely based on more detailed operating data.
View full abstract
-
Toshiaki OMORI, Shin-ichi TANABE
Article type: Article
Session ID: C-25
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Indoor thermal environment and thermal comfort are influenced by many factors such as building properties, heating systems, outdoor climate and occupants. In this paper, thermal environments and energy consumptions are analyzed by the coupled simulation of convection and radiation for a floor heating system and a wall-mounted air-conditioning unit under different thermal insulation levels. Thereafter, comprehensive evaluation is made using the comfort indices specified in ISO-7730.
View full abstract
-
Makoto TAKAHASHI, Takashi KURABUCHI, Shizuo IWAMOTO, Takeshi KONDOU, T ...
Article type: Article
Session ID: C-26
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study aims at evaluation of the indoor environments affected by characteristics of heating systems. Floor heating system and the air-conditioning unit using heat pump were tested in environmental chamber, equipped with suction type full time ventilation system. Indoor thermal environment was evaluated based on criteria recommended in ISO7730. The results were summerised that many people feels uncomfortable by draft and unsteady flow from air-conditioning unit, and affected by cold draft from air supply opening in the case of the floor heating system.
View full abstract
-
Akio TANAKA, Hidetoshi NAKAGAMI, Chiharu MURAKOSHI, Mikiko NAKAMURA
Article type: Article
Session ID: C-27
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study intends to clarify real usage of equipment and energy consumption in a residential house. This study researches a large number of households in 3 major cities via internet. This paper, as an interim report of the study, shows the purpose of the study, the methods, the characteristics of sample households, and real usage and conformability of heaters. This paper shows that a floor heating system has higher conformability and an air conditioner is used with higher temperature than a fan heater. The next paper will report a relation between usage of equipment and energy consumption.
View full abstract
-
Masayuki KAYAMA, Atsushi IWAMAE, Kyoji ISHIZU, Akiko ISHIGURO, Shuichi ...
Article type: Article
Session ID: C-28
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
It is not clarified that how and when people use heating apparatus in the bedroom in Kansai area. Moreover, we don't know which apparatus people use in their room, such as floor heating or air conditioner. Among various heating apparatus, we choose the floor heating system by the reason of its good thermal profile. In order to improve the thermal environment during sleeping by the floor heating system, researched the real states of heating usage and perform the questionnaire survey. And we estimate the influence of heating on thermal environment.
View full abstract
-
Takashi AKIMOTO, Yasuo KUWASAWA, Takuya KISIDA, Masahiko SATO
Article type: Article
Session ID: C-29
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
We conducted a subjective experiment in two experimental rooms. The rooms were a highly air-tight and insulated room, and a conventional energy saving room. In particular, we focused to the difference of heating floor panel between 60% and 30%. In addition, the difference between heating systems, the floor heating and the air-conditioner was also concerned. The recommended condition of air temperature and floor surface temperature for the highly and insulated room was shown comparing that for the previous type of room.
View full abstract
-
Maki OHASHI, Kazuo EMURA, Tadahiro TSUCHIKAWA, Teruyuki SAITO, Takayuk ...
Article type: Article
Session ID: C-30
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This experiment is done to see the effect that of a floor heater and an air-conditioner on female subjects. In the morning, those subjects keep at rest, and are exposed to the experiment for two hours in the highly air-tight and insulated room in the afternoon. The decrease of skin temperature, as which defined that the difference of the temperature between the navels and the right side of feet is above six degrees, is caused for each of heating system. The tendencies of skin temperature decreasing are divided into three types, one always keeps decreasing, one sometimes gets decreasing, the other dose not decrease any time.
View full abstract
-
Tsuyoshi SAOTOME, Shuzo MURAKAMI, Shinsuke KATO, Toshiaki OMORI
Article type: Article
Session ID: C-31
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study deals with the heat release characteristics of human body under various horizontal airflow environments. In the stagnant environment, the rising airflow is generated around human body. In horizontal airflow environment, the rising airflow is thrown to the leeward side when the air velocity is high. Micro-climate around human body formed under horizontal airflow environment with the air velocity as low as 0.05m/s is almost the same as the stagnant environment. The value of convective heat transfer coefficient of human body in horizontal airflow environment with air velocity of 0.5m/s is 2.5 times than the one in stagnant environment.
View full abstract
-
Tomonori SAKOI, Kazuyo TSUZUKI, Shinsuke KATO, Ryozo OOKA, Doosam SONG ...
Article type: Article
Session ID: C-32
Published: July 25, 2005
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Authors proposed a new three-dimensional human thermal model that satisfies the following four points. 1) The blood mass is conserved despite the vasoconstriction and vasodilation. 2) Three dimensional temperature distribution is produced in the human body. 3) Hot condition provokes increase of blood flow rate in superficial veins, 4) Thermal conduction in subcutaneous fat layer is calculated directly using temperature difference in this layer and the thickness of this layer. As the application of this model, the authors predicted thermal comfort in non-uniform clothing conditions reported by Olesen et al.(1988). The predicted comfort sensation agreed well with the reported results.
View full abstract