1984 年 100 巻 1161 号 p. 1080-1084
The mixed gas containing SO2 was blown into the H2O2 aqueous solution with a vertical down-blow nozzle. The absorption percentage of SO2 has been measured as a function of the nozzle diameter (1.25-5.9mm), the submerged depth of nozzle (L;-5-20cm) and the gas flow rate (30-80dm3/min). The jet trajectory length S (cm) were measured simultaneously, and the relationship among S, Reynolds number NRe and the absorption percentage of SO2 were considered.
When the gas was blown from a nozzle of small diameter, high absorption percentage of SO2 should be obtained even if the gas flow rate was low and the submerged depth of nozzle was shallow. SO2in the mixed gas would be absorbed perfectly by the solution when NRe and L satisfy the next equation.
NRe>245 (16-L)2 (-2≤L≤8)
It was found that S was given by
S=6.8×10-3NRe0.76+L(0≤L)
It seems advantageous to let the nozzle be submerged deep to gethigher fraction reacted in the injection with a vertical down-blow nozzle.