p. 47
In this paper, we propose a new modeling method of stoker-type incinerator for refuse incineration plants in order to analyze dynamic behavior of refuse combustion process and refuse movements. The refuse incinerator model is represented by a mathematical model taking into account various kinds of refuse drying, pyrolysis, gasification and combustion process, refuse moving process, gas combustion process, etc., can simulate the dynamic behavior of refuse combustion process and refuse movements at the change of running commands, e.g. refuse inputs, combustion air, and stoker movements.