Development of Temperature and Vapor Pressure Deficit Control System Using Variable Rate Fogging in Plant Factory with Solar Light
Kouichi WATANABEYosuke ASANOIkusaburo KURIMOTOTsunaki NUKAYAAtsushi KANOToru MARUO
Author information
JOURNAL FREE ACCESS

2016 Volume 52 Issue 5 Pages 292-298

Details
Abstract
We report the construction of temperature and VPD (Vapor Pressure Deficit) control system. In the plant factory with solar light, the control method for temperature and VPD using fogging system was not confirmed in the previous research. We propose the control method for temperature and VPD using variable rate fogging system by VPD feedback control to improve the growing environment of the plant. We subjected evaluation and review of the system that adjusts the fogging rate based on the VPD, and performs variable fogging. As a result, it increased the tomato fruit yield about from 10% to 20% more than the control area by proposed system in summer and winter.
Content from these authors
© 2016 The Society of Instrument and Control Engineers