柔軟膜ひずみセンサを用いた嚥下障害リハビリテーションのための喉頭挙上の検出
勝野 友基中本 裕之山本 暁生梅原 健別所 侑亮小林 太寺田 努石川 朗
著者情報
ジャーナル フリー

2019 年 55 巻 10 号 p. 655-661

詳細
抄録

The Mendelsohn maneuver is one of dysphagia rehabilitation methods and is a swallowing maneuver which voluntarily prolongs laryngeal elevation. In general, the recognition of the laryngeal elevation is difficult for patients. They often need a long-time training to obtain the maneuver. However, showing onset and offset times of laryngeal elevation can promote effective rehabilitation. We propose a measurement device of the laryngeal elevation based on the change of the circumference of the neck. In this study, we develop a neckband-shaped device composed of stretchable strain sensors. The laryngeal elevation changes the neck circumference. The device partially measures the neck circumference. Two methods detect the onset and offset times of the laryngeal elevation. One determines the times from the difference of the time-series circumference of the neck. The other method determines the times from both the difference and a pattern matching. In experiments, 21 healthy subjects conducted 4-second laryngeal elevation in the Mendelsohn maneuver. Simultaneously, a speech-language-hearing therapist determined the times of the laryngeal elevation by palpating the subjects. The method of only the difference correctly detected the onset times. However, the offset times had over 1-second errors in some cases. The other method detected both the onset and offset times with short-time errors. We confirmed that the proposed device and the method with the difference and pattern matching have a potential for a biofeedback rehabilitation device.

著者関連情報
© 2019 公益社団法人 計測自動制御学会
前の記事
feedback
Top