計測自動制御学会論文集
Online ISSN : 1883-8189
Print ISSN : 0453-4654
ISSN-L : 0453-4654
2成分系精留塔の動特性(その1)
還流液流量変化に対する過渡応答の実測結果
加藤 洋明
著者情報
ジャーナル フリー

1967 年 3 巻 2 号 p. 83-86

詳細
抄録
Experimental transient response data are presented for a twenty one-tray, 320mm diameter, bubble cap distillation column when a sudden change in reflux flow-rate is introduced. The column operated with the water-methanol system. The experimental transient response curves are distinguished into two regions, one is a short time region immediately after a change in reflux flow-rate where the response is determined mainly by transfer lag of a liquid stream in the column, the other is a long time region after the above mentioned region where the response is determined mainly by mass transfer. The response by mass transfer has very significant nonlinearity for a reflux flow-rate increase and decrease.
著者関連情報
© 社団法人 計測自動制御学会
次の記事
feedback