測地学会誌
Online ISSN : 2185-517X
Print ISSN : 0038-0830
ISSN-L : 0038-0830
ローラー型伸縮計のレーザを用いたCalibrationについて
竹本 修三
著者情報
ジャーナル フリー

1975 年 21 巻 2 号 p. 81-90

詳細
抄録

A “roller” extensometer was calibrated using a Michelson-type interferometer with a He-Ne laser source. This calibration system was capable of detecting relative displacements smaller than 0.016μm. The super-invar rod of the extensometer was displaced longitudinally about 2-7μm with a heating element consisting of a wire-wound bar of glass and a reflecting aluminum plate. The resultant displacement was detected by reading the fringe displacement records which had been converted photo-electrically by two differential photodiodes . As a result of this calibration, it was found that the sensitivity of the “roller” extensometer, which had been calculated from the radius of a roller and the optical length, was about 3560% of the true value for the range of the relative displacement amplitude of ±1-3μm.

著者関連情報
© 日本測地学会
前の記事 次の記事
feedback