Risk factors for clinically relevant loosening of percutaneous pedicle screws
Tetsuro OhbaShigeto EbataHiroki ObaKensuke KoyamaHirotaka Haro
Author information
JOURNAL OPEN ACCESS Advance online publication
Supplementary material

Article ID: 2018-0018

Details
Abstract

Objectives: (1) To evaluate the influence of pedicle screw loosening on clinical outcomes; (2) to clarify the association between the pull-out length and screw loosening 1 year after surgery; and (3) to determine radiographically which screw parameters predominantly influence the pull-out resistance of screws.

Methods: We analyzed 32 consecutive patients who underwent minimally invasive lumbar or thoracic spinal stabilization by intraoperative three-dimensional computed tomography (CT)-guided navigation without anterior reconstruction and were followed up for 1 year. The screw pull-out length was measured on axial CT images obtained both immediately after screw insertion and postoperatively. Loosening of screws and clinical outcomes were evaluated radiographically, clinically, and by CT 1 year after surgery.

Results: There were no significant differences in the mean age, sex, bone mineral density, mean stabilized length, and smoking habits of patients with (+) or without (–) loosening. The Oswestry Disability Index and the lumbar visual analog scale 1 year after surgery were significantly higher in patients with loosening (+) than in those without (–). The overall pedicle screw pull-out rate was 16.2% (47/290) of screws and the overall screw loosening rate was 15.2% (44/290) of screws. Screws with loosening (+) had significantly lower (axial) trajectory angles and higher screw pull-out lengths than those without (–). Approximately 82% of loosened screws had been pulled out during rod connection.

Conclusion: A lower axial trajectory and an increased screw pull-out length after rod reduction are crucial risk factors for screw loosening.

Content from these authors
© 2018 The Japanese Society for Spine Surgery and Related Research.

SSRR is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. Anyone may download, reuse, copy, reprint, or distribute articles published in the journal for not-for-profit purposes if they cite the original authors and source properly. If you remix, transform, or build upon the material, you may not distribute the modified material.
https://creativecommons.org/licenses/by-nc-nd/4.0/