Introduction: This study aimed to evaluate the association between postoperative laminoplasty opening angle and hinge union, and to investigate the relationship between hinge fracture and subsequent hinge non-union.

Methods: Sixty-eight patients (autograft, n = 29; plate, n = 39) underwent open-door cervical laminoplasty by a single surgeon with ≥1-year follow-up. Patient-level complete union was defined as union across all operated laminae on 1-year computed tomography. Mean opening angle, canal expansion, cervical alignment, and clinical outcomes were evaluated. Receiver operating characteristic (ROC) analysis evaluated the relationship between mean opening angle and union; multivariable logistic regression identified independent predictors of union. Lamina-level analyses assessed opening angle, hinge fracture, union, and implant size.

Results: Patient-level union occurred in 41 of 68 patients (60%). ROC analysis showed moderate discrimination (area under the curve = 0.70); union was more frequent in patients with mean opening angles <40° than in those with mean opening angles ≥40° (77% vs. 44%, p = 0.013). A larger mean opening angle was independently associated with a lower likelihood of union, whereas fixation method and the number of levels operated on were not. Complete union rates did not differ significantly between the autograft and plate groups (72% vs. 51%, p = 0.087). Complete union was associated with a lower incidence of axial neck pain at 1 year (4.9% vs. 25.9%, p = 0.024). At the lamina level, larger opening angles were associated with hinge fracture and lower union rates. Larger plates were associated with greater opening angles but were not significantly associated with hinge fracture or union.

Conclusions: Larger postoperative opening angles were associated with hinge fracture and non-union, suggesting that excessive opening should be avoided. Because larger plate sizes were associated with greater opening angles, careful plate-size selection may help avoid unnecessarily large laminar opening. Complete hinge union was also associated with a lower incidence of axial neck pain.

Content from these authors
© 2026 The Japanese Society for Spine Surgery and Related Research.

SSRR is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. Anyone may download, reuse, copy, reprint, or distribute articles published in the journal for not-for-profit purposes if they cite the original authors and source properly. If you remix, transform, or build upon the material, you may not distribute the modified material.