抄録
Assembly tolerance of members of a structure causes eccentricity of an axial line of the member. In the case that the members is high strength bolted friction type joint, one of the assembly tolerances is an irregularity of connected plates in lateral direction. This paper evaluates the effect of the irregularity of connected plates of the joint to its slip strength. The strength is evaluated by FEM analysis. Behavior of bolt tightening and the slip strength of joints whose connected surface attached closely or attached with interspace is compared and discussed.