構造工学論文集 A
Online ISSN : 1881-820X
合成・複合構造
グループスタッドを配置したプレキャスト床版合成桁の詳細挙動に関する基礎実験
中島 章典岡崎 康幸Duong Nguyen Van
著者情報
ジャーナル フリー

2015 年 61A 巻 p. 788-797

詳細
抄録
The precast slab with the void part for stud arrangement is sometimes used in exchanging the RC slab due to shortening of a construction period and arrangement of shear connectors. Then, it is required to investigate the composite action between the steel girder and the precast slab with the grouped studs in detail, and the effect of installing the precast slab partially. In this study, we conducted the composite girder test having the precast slab with the grouped studs and the one having the RC slab with the normal stud arrangement. As a result, the static behavior are compared between both composite girders and the corresponding push-out specimens, and the composite action of the girder with the precast slab is clarified in detail.
著者関連情報
© 2015 公益社団法人 土木学会
前の記事 次の記事
feedback
Top