構造工学論文集 A
Online ISSN : 1881-820X
構造安定・耐荷力・構造一般
内面が腐食した補剛板の耐荷力評価に関する解析的基礎検討
廣澤 直人山口 隆司高田 佳彦
著者情報
キーワード: 補剛板, 腐食, 耐荷力, 縦補剛材
ジャーナル フリー

2018 年 64A 巻 p. 51-59

詳細
抄録

The inner surface of steel footing got corroded by the unexpected increase in the groundwater level. Its load capacity might be reduced due to the corrosion. FEM analysis was carried out the stiffened plate with a corroded inner surface, then the influence of the corrosion of the panel and the longitudinal stiffener on the ultimate strength was investigated. Especially, this analysis focused on a simple corrosion shape in order to obtain the lower limit of the reduction of ultimate strength. As a result, it was clarified that ultimate strength and deformation mode are different depending on the corrosion rate and shape.

著者関連情報
© 2018 公益社団法人 土木学会