2024 年 70A 巻 p. 639-646
The metal-sprayed surface and hot-dip galvanized surface are often applied to high strength bolted joints and bolts in those joints are tightened by turn-of-nut method. However, it is still not enough clear how much axial force is induced into bolts by difference of bolt diameter. In this paper, we investigated characteristics of induced axial force by literature search in high strength bolted joints using turn-of-nut method. From the results, we show difference of induced axial force by bolt diameter.