NIPPON SUISAN GAKKAISHI
Online ISSN : 1349-998X
Print ISSN : 0021-5392
ISSN-L : 0021-5392
An Assay Method for Freshness of Fishes by the Estimation of pH Value
Makoto YAMAMOTOMasanori SONEHARA
Author information
JOURNAL FREE ACCESS

1953 Volume 19 Issue 6 Pages 761-765

Details
Abstract

Present paper concerns with the accuracy and usefulness of pH determination in terms of freshness of fishes. A special glass electrode (Fig. 1) connected with an amplifier capable of reading exactly 0.50mV intervals was used. The results obtained are shown in Fig. 2-5 and Tab. 1-4, and may be summarized as follows: (1) The pH value of fish meats will be adopted as a criterion of the freshness of fishes to some extent. (2) However, the pH value varies according to the part of a body. And some divergencies are also observed according to the fishing season and species of fishes. (3) The pH value of fish meats at the early spoilage was 6.85 in the fishes of white meat and 6.27 in those of red meat.

Content from these authors
© The Japanese Society of Fisheries Science
Previous article Next article
feedback