日本原子力学会和文論文誌
Online ISSN : 2186-2931
Print ISSN : 1347-2879
ISSN-L : 1347-2879
論文
Design-by-Analysis と試験による低圧損気水分離器の開発(II)
実規模試験による低圧損気水分離器性能の実証
岩城 智香子山崎 之崇師岡 慎一山田 勝己池田 浩楊井 知啓曽根田 秀雄
著者情報
ジャーナル フリー

2010 年 9 巻 2 号 p. 118-124

詳細
抄録

  The purpose of this study is to develop a new BWR steam separator with a lower pressure loss of more than 20% than the current steam separator while maintaining the steam separation performance. Reducing the pressure loss of steam separators is advantageous in that it reduces the required recirculation pump power and hence increases the net electrical power output. In previous studies, a low-pressure-loss steam separator was developed by three-dimensional two-phase flow simulations verified by 1/2.22-scale model experiment. In this study, performance tests for a full-scale steam separator with an improved swirler were conducted under actual reactor operating conditions of 7.17 MPa and 287°C. The obtained results demonstrate that pressure loss decreases by about 25% and the separation performance is similar to that of the current steam separator under rated reactor conditions.

著者関連情報
© 2010 一般社団法人 日本原子力学会
前の記事 次の記事
feedback
Top