日本原子力学会和文論文誌
Online ISSN : 2186-2931
Print ISSN : 1347-2879
ISSN-L : 1347-2879
423. 高温ガス炉HTTRの冷却材中の化学的不純物特性
坂場 成昭中川 繁昭古澤 孝之江森 恒一橘 幸男
著者情報
ジャーナル フリー

2004 年 3 巻 4 号 p. 388-395

詳細
抄録

Chemistry control is important for the helium coolant of High Temperature Gas-cooled Reactors (HTGRs) because impurities cause oxidation of the graphite used in the core and corrosion of high temperature materials used in the heat exchanger. In the High Temperature Engineering Test Reactor (HTTR) which is the first HTGR in Japan, the chemical impurity concentration is restricted and its behaviour is monitored during reactor operations. The impurity is reduced by the helium purification system and the concentration is measured by the helium sampling system installed to the primary and secondary helium system, continuously. This paper describes the impurity behaviour during the rise-to-power test which is the initial power-up of the HTTR. Also, the amount of the emitted impurity to the primary circuit from the graphite component and insulator used at the concentric hot gas duct are evaluated. During the power up, any abnormal impurity increases were not obtained and the chemical composition of the primary circuit was sufficiently in the stability area to avoid carbon deposition.

著者関連情報
© by the Atomic Energy Society of Japan
前の記事 次の記事
feedback
Top