Heat Exchanger Performance in Main Cooling System on High Temperature Test Operation at High Temperature Gas-Cooled Reactor 'HTTR'
Daisuke TOCHIOShigeaki NAKAGAWATakayuki FURUSAWA
Author information
JOURNAL FREE ACCESS

2005 Volume 4 Issue 2 Pages 147-155

Details
Abstract
High Temperature Engineering Test Reactor (HTTR) of high temperature gas-cooled reactor at Japan Atomic Energy Research Institute achieved the reactor outlet coolant temperature of 950°C for the first time in the world at Apr. 19, 2004. To remove generated heat at reactor core and to hold reactor inlet coolant temperature as specified temperature, heat exchangers in HTTR main cooling system should have designed heat exchange performance.
In this report, heat exchanger performance is evaluated based on measurement data in high temperature test operation. And it is confirmed the adequacy of heat exchanger designing method by comparison of evaluated value with designed value.