Seismic Fragility Capacity of Equipment
Horizontal Shaft Pump Test
Toru IIJIMAHiroshi ABEKenichi SUZUKI
Author information
JOURNAL FREE ACCESS

2006 Volume 5 Issue 3 Pages 200-208

Details
Abstract
Seismic probabilistic safety assessment (PSA) is an available method to evaluate residual risks of nuclear plants that are designed on definitive seismic conditions. From our preliminary seismic PSA analysis, horizontal shaft pumps are important components that have significant influences on the core damage frequency (CDF). An actual horizontal shaft pump and some kinds of elements were tested to evaluate realistic fragility capacities. Our test results showed that the realistic fragility capacity of horizontal shaft pump would be at least four times as high as a current value, 1.6×9.8m/ss2, used for our seismic PSA. We are going to incorporate the fragility capacity data that were obtained from those tests into our seismic PSA analysis, and we expect that the reliability of seismic PSA should increase.