TRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, AEROSPACE TECHNOLOGY JAPAN
Online ISSN : 1884-0485
ISSN-L : 1884-0485
i) Thermal Control
Experimental Study of Effects of Secondary Wick Configuration on Thermal Performance of Loop Heat Pipe
Hiroki NAGAIMasahiko TAKETANITakuya ADACHITakurou DAIMARU
著者情報
ジャーナル フリー

2016 年 14 巻 ists30 号 p. Pi_7-Pi_15

詳細
抄録

In this study, we experimentally investigated the effects of the secondary wick configuration on the thermal performance of a loop heat pipe (LHP). The results indicated that two important factors affect the heat transfer characteristics: (1) contact area between the secondary wick and the reservoir, and (2) cross-sectional area of evaporator core. We then propose a desirable secondary wick configuration by considering these two factors.

著者関連情報
© 2016 The Japan Society for Aeronautical and Space Sciences
前の記事 次の記事
feedback
Top