鉄と鋼
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
論文
超音波探傷法による連鋳スラブ中欠陥分布評価と鋳型内の電磁ブレーキによる偏流低減効果
古米 孝平松井 穣村井 剛三木 祐司
著者情報
ジャーナル オープンアクセス HTML

2014 年 100 巻 4 号 p. 563-570

詳細
抄録

In order to clarify the mechanism of suppression of unbalanced flow in the mold under high throughput conditions in continuous casting, the relationship the distribution of defects entrapped in the solidified shell was measured by ultrasonic defect detection, and the correlation between the defects distribution and the unbalanced flow in the mold when using an electromagnetic brake was investigated. The main results are summarized as follows.
(1) By using a new ultrasonic testing system, rapid and accurate measurement could be achieved for the depth of defects with diameters of more than 0.6 mm in the region 2-10 mm from the slab surface.
(2) The measured value of the effect of the electromagnetic brake on decreasing molten steel momentum was consistent with the calculated value. Molten steel momentum could be reduced by more than 50% when the Stuart number was more than 3.5.
(3) The position of entrapped defects in the solidified shell in the mold was influenced by the throughput condition and the magnetic flux density of the electromagnetic brake.

著者関連情報
© 2014 一般社団法人 日本鉄鋼協会

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/