鉄と鋼
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
技術報告
陽イオン交換ディスクを用いた固相抽出分離/ICP-MSによる鉄鋼分析
長谷川 信一
著者情報
ジャーナル オープンアクセス

2009 年 95 巻 12 号 p. 911-914

詳細
抄録

A simple pretreating method which consists of solid phase extraction using cation exchange extraction disk was tried for the determination of trace elements in iron and steel samples by means of inductively coupled plasma mass spectrometry (ICP-MS). The sample of 0.100 g was dissolved by nitric acid, subsequently adding 8 cm3 of 10w/v% ethylenediaminetetraacetic acid disodium salt (EDTA) solution as masking agent for the iron matrix. The sample solution was adjusted by the dilution with water to pH 1.8 or more and poured into the extraction disk. The target elements retained in the extraction disk were then eluted using 10 cm3 of 3 kmol/m3 nitric acid. Quantities of the obtained target elements were determined using ICP-MS. Highly sensitive quantification was established for 6 trace elements in iron and steel, and for Ca, Mn, Mg, Ba, Tl and Sr with the following detection limits [3σ; ng/g (ppb)]: Ca: 4.75, Mn: 0.26, Mg: 0.40, Ba: 0.014, Tl: 0.033 and Sr: 0.11. This method is extremely easy, is rapid, the amount of the reagent used is a little, and a free skill and the zero emission are achieved.

著者関連情報
© 2009 一般社団法人 日本鉄鋼協会

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
前の記事 次の記事
feedback
Top