鉄と鋼
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
論文
減圧レーザ誘起プラズマ発光分析法を用いたFe基合金中Niの定量分析
阿部 千景我妻 和明
著者情報
ジャーナル オープンアクセス

2012 年 98 巻 2 号 p. 63-68

詳細
抄録

In order to evaluate the analytical precision in low pressure laser-induced argon plasma emission spectrometry (LIPS), we conducted the determination of Ni in Fe-based alloys to consider the most suitable measurement condition, in particular, a gas pressure of argon and several measuring parameters for time-resolved observation. The selection of emission lines was an important factor to obtain a liner calibration curve depending on the concentration of Ni. The precision was generally inferior to analytical results in XRF and ICP-OES. However, the analytical value of Ni was obtained with good reliability, by averaging during replicate measurements. It was further shown the Ni content in Fe-Ni-X alloys would be determined by using calibration curves estimated from binary Fe-Ni alloys.

著者関連情報
© 2012 一般社団法人 日本鉄鋼協会

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
前の記事 次の記事