鐵と鋼
Online ISSN : 1883-2954
Print ISSN : 0021-1575
熱風爐の構造とその熱能率に就て
海野 三朗
著者情報
ジャーナル フリー

1936 年 22 巻 3 号 p. 165-180

詳細
抄録
Temperature distributions in Three-pass stove and two Cowper stoves of different design in details at Yawata Steel Works, firing, gases and airs supplied to them were measured. From these results, heat efficiency of each hot stove was calculated, and firing gases were compared with the hot airs used to the blast furnaces. Moreover, actual amount of hot airs given, to the furnaces and produced gases recorded by each gas-meter, real amounts of them measured by the method of Pitot-tube and true values of them caleulated from ores and others are examined.