連続鋼片加熱炉における伝熱実験結果と総括熱吸収率について
松永 省吾
著者情報
ジャーナル フリー

1973 年 59 巻 2 号 p. 301-307

詳細
抄録

A study has been made of the total heat exchange factor in the steel slab reheating furnace based on the experimental data and the radiation heat transfer theory.
The total heat exchange factor φCG can be estimated as follows:
φCG=0.64 for heavy oil firing, and φCG=0.3 for gas firing
when the furnace gas temperature is determined by the readings of the thermocouple inserted into the furnace combustion chamber through the furnace wall.
By a heat transfer simulation using the value of φCG, an examination was made on HAYS'S experimental formula for the furnace retention time of slabs.