鉄と鋼
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
湿潤硫化水素環境下における長期実管曝露による鋼管の水素誘起われ
池田 昭夫寺崎 富久長小若 正倫
著者情報
ジャーナル オープンアクセス

1979 年 65 巻 3 号 p. 433-442

詳細
抄録
In order to investigate the hydrogen induced cracking (HIC) susceptibility of pipe sample in sour gas service, the container type specimen was used, of which body was made from the pipe tested. Three kinds of commercial large size line pipes of API 5LX-60 and X-65 grades were examined for this study. After the half of the volume was filled with test solutions, pure H2S gas or mixture of N2 and H2S was bubbled. The test solutions were synthetic sea water, pure water and synthetic sea water mixed with crude oil. After controlling the concentration of H2S, the containers were kept for about one year as they were. In order to know the development of cracking during the test, ultrasonic testing was used.
As the results of this investigation, it was clarified that the development of HIC was due to the environment, steels, mill scale and so on. It was also obtained that HIC susceptibility of steels evaluated by the standard HIC test method which was recently developed by Kowaka et al, correlated wtih that evaluated by this long duration exposure test, although the investigation of environmental factors was important for the prevention of HIC.
著者関連情報
© 一般社団法人 日本鉄鋼協会

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
前の記事 次の記事
feedback
Top