鉄と鋼
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
熱間圧延における高圧水脱スケール時の鋼材の温度低下
和田 忠義押見 正一上田 正雄
著者情報
ジャーナル フリー

1991 年 77 巻 9 号 p. 1458-1464

詳細
抄録

When scale formed during reheating and continuous rolling of steel strips is commonly by hydraulic descaling, a temperature drop of the strips inevitably occurs.
On an experimental survey of parameters which had been expected to control the descaling behaviours, the temperature drop of steel strips on removing the secondary scale by hydraulic descaling was measured precisely on the basis of design of experiments. It was found that the temperature drop has correlations with the water consumption V at a pressure of 9.8 MPa, interaction between V and the distance H between the steel and the nozzle, water pressure P.
The temperature drop ΔTD(°C) of steel strips by hydraulic descaling can be then expressed by the descaling parameters as follows;
ΔTD= 451.7 PV/H2+9.54
It is concluded that H should be increased with V to keep the temperature drop small when a certain pressure impact pressure is required to remove the secondary scale.

著者関連情報
© 一般社団法人 日本鉄鋼協会
前の記事 次の記事