鉄と鋼
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
多波長温度計の開発と亜鉛メッキ合金化炉への適用
山本 俊行平本 一男植松 千尋上田 潤
著者情報
ジャーナル フリー

1993 年 79 巻 7 号 p. 779-785

詳細
抄録

The multiwavelength pyrometry problem of inaccuracy in determining the true temperature has been analysed in detail. The results of this analysis and a comparison with numerical simulation results show that a proper calculation method of a temperature and a certain knowledge on the emissivity of the target surface are indispensable to an accurate temperature determination. On the basis of this study a new multiwavelength pyrometer for the use of the galvanneal process is developed with a careful design. In spite of the greately changing characteristics of the target surface emissivity in the galvanneal process, where zinc-coated steel sheet is rapidly annealed to produce desirable intermetallic coated layer and the surface of the zinc layer changes from highly specular reflectivity with emissivity near 0.1 to a nearly diffuse reflectivity with emissivity as high as 0.7, this new pyrometer is effectively applied and the measurement accuracy is confirmed to be ±10% for temperature and ±10% for emissivity by laboratory simulations and on-line tests.

著者関連情報
© 一般社団法人 日本鉄鋼協会