鉄と鋼
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
圧力容器用低合金鋼SQV2Aの高温高圧水中低サイクル疲労挙動に及ぼすすき間効果
佐藤 俊司片田 康行永田 徳雄
著者情報
ジャーナル オープンアクセス

1995 年 81 巻 8 号 p. 827-832

詳細
抄録
The effect of crevice on low cycle fatigue behavior of a low alloy steel JIS SQV2A (equivalent to ASTM A533B cl. 1) for reactor pressure vessel was investigated in high temperature pressurized water at 561K and 7.8Mpa. Crevice were made on the specimen surface by attaching a pair of split collars of the same material. The dissolved oxygen (DO) concentration was varied from 10 ppb to 4000 ppb.
The fatigue life was found longer for creviced specimens than that for no creviced ones, especially for low strain range. The same trend was observed at low DO concentration levels. In case of no creviced specimen, fatigue life was notably reduced for DO concentrations higher than 1000ppb.
It can be concluded that the extention of fatigue life of the creviced specimens is due to the reduction of DO concentraion in the crevice.
著者関連情報
© 一般社団法人 日本鉄鋼協会

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
前の記事 次の記事
feedback
Top