SUS304冷延焼鈍板の脱スケール性におよぼす酸化皮膜構造の影響
福田 國夫宇城 工佐藤 進太田 裕樹
著者情報
ジャーナル フリー

1998 年 84 巻 5 号 p. 345-350

詳細
抄録

In order to obtain good descalability of cold rolled and annealed Type 304 stainless steels, oxidation behavior and scale structure of the steels were investigated. The oxide scale consisted of four layers. The outer first layer was composed of Fe2SiO4 and Fe3O4, the second layer was (Fe, Mn) Cr2O4, the third layer was Cr2O3, and the fourth layer adjacent to substrate was amorphous oxide, SiO2. The third layer became thick and the Si content in the fourth layer increased with the rise of annealing temperature. The thick third layer provided a large Cr depletion zone at the surface layer of substrate. Thus, annealing at higher than 1125°C to develop the Cr depletion zone is effective to obtain good descalability in Type 304 stainless steels.