Tetsu-to-Hagane
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
Particle Image Velocimetry (PIV) Measurement of Flow Establishment Time in a Bath Agitated by Plunging Jet
Tomoyuki SHIMIZUManabu IGUCHINorihisa TSUDA
Author information
JOURNAL OPEN ACCESS

2001 Volume 87 Issue 9 Pages 571-578

Details
Abstract
The instantaneous velocity of flow in a water bath agitated by a plunging water jet was measured with particle image velocimetry (PIV). The water in the bath was initially at rest and then driven by the plunging water jet. The period from the start of plunging to the moment at which the flow in the bath becomes a steady state is defined as flow establishment time. The turbulence components were used to determine the flow establishment time in place of the commonly used mean velocity components. An empirical equation was proposed for the flow establishment time.
Content from these authors
© The Iron and Steel Institute of Japan

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Next article
feedback