鉄と鋼
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
種々の埋没材を用いて歯科精密鋳造した生体用Ti-29Nb-13Ta-4.6Zr合金の引張特性と鋳造欠陥との関係
新家 光雄赤堀 俊和眞鍋 哲典竹内 力桂 成基福井 壽男鈴木 昭弘
著者情報
ジャーナル オープンアクセス

2004 年 90 巻 10 号 p. 827-834

詳細
抄録
Relationship between tensile properties and casting defect of newly developed β type titanium alloy, Ti-29Nb-13Ta-4.6Zr, for biomedical applications, and representative α+β type titanium, Ti-6Al-4V ELI, for biomedical applications cast by dental precision casting using commercial alumina, magnesia and modified magnesia based investment materials. Then the effect of specimen diameter on tensile properties of both cast alloys was also investigated.
Elongation of cast tensile specimens of both alloys slightly increases and strength of cast tensile specimen of Ti-6Al-4V ELI increases with reducing casting defects. Hardness of surface reaction layer decreases, and hardness of matrix decreases by about 50 Hv due to increasing cooling rate by reducing the specimen diameter from 3 to 2 mm in both alloys. The microstructures of both cast alloys refines with reducing specimen diameters, and the hardness of surface reaction layers and matrix of both alloys decreases. Therefore, increasing strength of cast Ti-6Al-4V ELI with reducing specimen diameter is attributed to reducing casting defects.
著者関連情報
© 一般社団法人 日本鉄鋼協会

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
前の記事 次の記事
feedback
Top