Study of the Location of the Minimum Fo Value during the Thermal Processing of Food Packages Containing Air
Shoichi Inaba
Author information
RESEARCH REPORT / TECHNICAL REPORT FREE ACCESS

2025 Volume 35 Pages 65-69

Details
Abstract
The effect of the air-containing part of food packages on the location of the minimum Fo value was investigated. A 6% gelatinized starch liquid was packed into a cylindrical cup also containing air, and the temperature was measured at six points on the central vertical axis during thermal processing at 120 °C for 30 minutes. As a result, the position where the Fo value was at a minimum was found to be closer to the air-containing part than to the geometric center of the cylinder. When the temperature curves at each position were analyzed using the delay time (δ) of the ATS method, it was confirmed that the minimum Fo value occurred where the temperature rise was slow and the cooling was fast. These minimum Fo values were approximately 10% to 15% of the Fo value at the geometric center position. It is thus necessary to consider the risks of an inadequate thermal treatment due to assuming an incorrect temperature measurement location by not taking air pockets into account.
Content from these authors
© 2025 Toyo Institute of Food Technology
Previous article Next article
feedback
Top