IEICE Transactions on Communications
Online ISSN : 1745-1345
Print ISSN : 0916-8516
Special Section on Telecommunication Energy Technology in Conjunction with Main Topics of INTELEC'09
Totem-Pole Power-Factor-Correction Converter under Critical-Conduction-Mode Interleaved Operation
Eka FIRMANSYAHSatoshi TOMIOKASeiya ABEMasahito SHOYAMATamotsu NINOMIYA
著者情報
ジャーナル 認証あり

2010 年 E93.B 巻 9 号 p. 2250-2256

詳細
抄録
This paper proposes a new power-factor-correction (PFC) topology, and explains its operation principle, its control mechanism, related application problems followed by experimental results. In this proposed topology, critical-conduction-mode (CRM) interleaved technique is applied to a bridgeless PFC in order to achieve high efficiency by combining benefits of each topology. This application is targeted toward low to middle power applications that normally employs continuous-conduction-mode boost converter.
著者関連情報
© 2010 The Institute of Electronics, Information and Communication Engineers
前の記事 次の記事
feedback