日本伝熱学会論文集
Online ISSN : 1882-2592
Print ISSN : 0918-9963
ISSN-L : 0918-9963
熱伝導率が小さく厚い試験片の厚さ方向定常熱伝導率測定法
岩本 直樹, 大串 哲朗, 村上 泰城, 村上 政明
著者情報
ジャーナル フリー

2020 年 28 巻 4 号 p. 45-51

詳細
抄録
For the measurement of the thermal conductivity of an electrical conductor laminated by insulating material, measurement accuracy by conventional steady state longitudinal heat flow method is decreased by the effect of heat loss from the specimen surface to ambient. We have developed “Modified Temperature Profile method (MTP method)” by modifying the conventional method to measure thermal conductivity of a thick specimen with low thermal conductance ranged from 10 to 100 W/(㎡・K). The temperature profile in the thick specimen with low thermal conductance is not linear, which is the main reason of the large measurement error in the conventional method. So, we applied the analytical solution of the straight fin for the temperature profile of the specimen. We successfully demonstrated that the measured thermal conductivities by MTP method were within ±10% error band by experiments using single component specimens made of acrylic plates and composite specimens consisted of copper and acrylic plates alternately piled up, which thermal conductance was ranged from 10 to 250W/(㎡・K).
著者関連情報
前の記事 次の記事
feedback
Top