Analysis of transient voltage and currept in theload change of medium-wave radio transmitter
Tetsurou MiyasakiKazuhisa HayeiwaHisashi NakaTakehiko YamaguchiYoshihiko Nasu
Author information
RESEARCH REPORT / TECHNICAL REPORT FREE ACCESS

1991 Volume 15 Issue 9 Pages 43-48

Details
Abstract

When the load condition of the transmitter changes by the antenna-induced lightning surges, large transfent voltage and current which may damage the power devices occur in the transmitter. In this paper, we analyze them by computer simulation, and show that the load impedance seen from the power amplifier with antenna base sborted should be approximately equal (inductive load), or twice (capacitive load) to the abselute value of the matched load impedance.

Content from these authors
© 1991 The Institute of Image Information and Television Engineers