Yonago Acta Medica
Online ISSN : 1346-8049
ISSN-L : 0513-5710
Original Article
A New Method of Microcatheter Heat-Forming for Cerebral Aneurysmal Coiling Using Stereolithography Three-Dimensional Printed Hollow Vessel Models
Sadao NakajimaMakoto SakamotoHiroki YoshiokaTetsuji UnoMasamichi Kurosaki
Author information
JOURNAL FREE ACCESS

2021 Volume 64 Issue 1 Pages 113-119

Details
Abstract

Background To perform successful coil embolization of cerebral aneurysms, it is crucial to make an appropriately shaped microcatheter tip for an aneurysm and its parent artery. So far, we manually shaped a mandrel by referencing two-dimensional (2D) images of a rotation digital subtraction angiography (DSA) on a computer screen. However, this technique requires a lot of experience, and often involves trial and error. Recently, there have been increasing reports of manual mandrel shaping using a full-scale three-dimensional (3D) model of an aneurysm and its parent artery output by various types of 3D printer. We have further developed this method by producing a hollow model of an aneurysm and its parent artery with a stereolithography 3D printer and inserting a mandrel inside the model to fit and stabilize a microcatheter tip.

Methods Based on digital imaging and communications in medicine (DICOM) data obtained by rotational DSA, 3D images of an aneurysm and its parent artery were created and converted into standard triangulated language (STL) data. A hollow model was produced by extruding the STL data outward in the normal direction, and then a hole was made at the tip of the aneurysm using these STL data. We output these STL data to a stereolithography 3D printer. After cleaning and sterilizing the model, the mandrel was inserted in the direction of the parent artery through the hole made in the tip of the aneurysm and pushed in, creating the ideal mandrel shape. Twelve cases (14 aneurysms) were included in this study. A microcatheter tip was shaped by this method for patients who were scheduled to undergo coil embolization for an unruptured aneurysm.

Results In 13 of the 14 aneurysms, the microcatheter was easily guided into the aneurysms in one or two trials, the position of the microcatheter tip in the aneurysm was appropriate, and the stability during coil embolization was high.

Conclusion Our method differs from the conventional one in that a hollow model made of resin is produced with a stereolithography 3D printer and that the mandrel is shaped by inserting it retrogradely into the hollow model. Using our new method, it will be possible to shape the tip of a microcatheter suitable for safe and stable coil embolization without relying on an operator’s experience.

Content from these authors
© 2021 Tottori University Medical Press
Previous article Next article
feedback
Top